Contact

General Requirements

How to install Braille and Tactile Signs
Figure 1

Accessible wayfinding signage provides significant benefits for visitors and the general public. When information is provided in formats that can be used by people with different abilities, it is easier for them to find their destination independently and safely.

Where Braille and tactile signage is required, it should be positioned at an accessible height and installed so that it can be readily located and read. High-level signage should be complemented by accessible signage at a suitable height where required.

The design and installation requirements for Braille and tactile signage are set out in Specification 15 of the National Construction Code (NCC). AS 1428.1:2021 also contains requirements relevant to access and mobility in new building work. The applicable NCC edition and any state or territory variations should be checked for each project.

International Symbol of Access

The International Symbol of Access, commonly referred to as the wheelchair symbol, is used to identify accessible facilities and features. Where the symbol is required, its design, contrast, finish and use should comply with the applicable NCC and Australian Standard requirements. A blue-and-white colour scheme is commonly recognised, but colour alone should not be treated as evidence that a sign is compliant.

Where Braille and tactile signs are required

Braille and tactile signage is not limited to accessible sanitary facilities. The NCC requires Braille and tactile signs in a number of circumstances, including for the identification of certain accessible facilities and spaces, and for particular doors associated with building egress. Requirements should be checked for each building and location rather than assuming that accessible toilet signs are the only signs required.

Toilet Signs

Signs should be provided to identify sanitary facilities where required by the NCC, including accessible unisex and ambulant facilities. The wording, symbols and location of each sign should accurately identify the facility provided.

An accessible sanitary facility sign should include the International Symbol of Access and the required Braille and tactile information. Where a sanitary facility includes an accessible shower, the sign should also identify the shower facility where required.

Signs identifying rooms containing facilities required to be identified should be installed on the latch side of the door. The leading edge of the sign must be located between 50 mm and 300 mm from the architrave. Where installation in that position is not possible, the NCC permits the sign to be placed on the door itself.

How to install Braille tactile signs for disabled toilets

Installation height

  • Braille and tactile components of a sign must be located not less than 1200 mm and not higher than 1600 mm above the floor or ground surface.
  • For a sign containing a single line of characters, the line of tactile characters must be located not less than 1250 mm and not higher than 1350 mm above the floor or ground surface.
  • Measurements should be taken to the relevant Braille or tactile component, not simply to the top, bottom or centre of the sign panel.

Braille and tactile sign requirements

Correct mounting height is only one part of compliance. The sign itself must also satisfy the applicable technical requirements. Under NCC Specification 15, these include requirements for tactile character height, character size, spacing, edges, surface finish and text alignment.

  • Tactile characters must be raised or embossed between 1 mm and 1.5 mm.
  • Title Case must be used for tactile characters.
  • Uppercase tactile characters must generally be between 15 mm and 55 mm high, with lower-case characters at least 50% of the associated uppercase character height.
  • Tactile characters, symbols and sign edges must be rounded.
  • The sign background and its characters, symbols, logos and other features must have a matt or low-sheen finish.
  • Tactile characters must have minimum letter spacing of 2 mm and minimum word spacing of 10 mm.
  • Tactile text must be left justified, although a single word may be centre justified.
  • Braille, tactile characters and symbols must be accurate, legible and provide the required luminance contrast.

 

How do I know if my toilet is LH or RH?

The “LH” or “RH” shown on an accessible sanitary facility sign identifies the direction of transfer from a wheelchair onto the toilet seat. The designation is determined while facing the toilet from the front:

  • RH indicates a transfer to the right onto the toilet seat, with the wall-mounted grabrail on the user’s right-hand side.
  • LH indicates a transfer to the left onto the toilet seat, with the wall-mounted grabrail on the user’s left-hand side.

The transfer designation on the sign should always be checked against the completed layout. Reversed or incorrect transfer-direction signs are a common installation error.

Types-of-Transfer-RH-Sign-or-LH-Sign

Common installation errors

  • Installing the sign above or below the permitted height range.
  • Measuring to the sign panel rather than to the relevant tactile characters or components.
  • Installing the sign on the hinge side instead of the latch side of the door.
  • Locating the leading edge of the sign more than 300 mm from the architrave.
  • Mounting the sign on the door when suitable latch-side wall space is available.
  • Using glossy or highly reflective materials that make the sign difficult to read.
  • Providing insufficient luminance contrast between the sign information and its background.
  • Using incorrect Braille, tactile character dimensions, spacing or transfer-direction symbols.
  • Allowing furniture, fittings or other objects to obstruct access to the sign.

Check the completed installation

Braille and tactile signage should be checked after installation. The review should confirm the sign content, mounting height, latch-side location, distance from the architrave, transfer direction, luminance contrast, surface finish and whether the sign can be approached and read without obstruction. Product selection and installation should be assessed together, as a compliant sign can become non-compliant if it is installed in the wrong location.

Get in touch

Our accredited access consultants provide disability access and egress consulting services to architects, developers, government bodies and organisations throughout Australia. Contact Equal Access for advice on Braille and tactile signage requirements, documentation reviews and completed installations.

References

  • National Construction Code 2025, Volume One, Specification 15 – Braille and tactile signs
    https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/d-access-and-egress/15-braille-and-tactile-signs
  • AS 1428.1:2021, Design for access and mobility, Part 1: General requirements for access – New building work
    https://store.standards.org.au/explore-standards/construction